kjhil.com

HCL Gas Absorber (Adiabatic Type)

Home »  Process Systems »  HCL Gas Absorber (Adiabatic Type)

HCL Gas Absorber (Adiabatic Type)

HCL absorption columns are used for absorption of Hydrochloric gas, which statutorily are not permitted to vent into the atmosphere, and to produce the HCl acid.

HCL Gas Absorber

The column is constructed with a series of packed sections, a gas introduction point below that, a condenser on the top, and a cooler at the bottom. Make water is sprayed from the top and acid is collected from the bottom.

HCL Gas Absorber 1

HCL absorption columns are available in 80DN to 300DN diameter (for the gas rate 10
Kgs/hr to 300 Kgs/hr approx).

HCL Gas Absorber (Adiabatic Type).

HCl gas can be economically absorbed forming Hydrochloric acid of 30% (w/w) concentration which can be re-used in the main process. Thus this absorption is a pollution abatement as well as a recovery process.

The absorption can be done by two different methods.

Adiabatic Absorption: This method is suitable when the inerts like air, phenolic compounds etc are substantial.

Isothermal Absorption: This method is suitable when inerts like air phenolic compounds, etc ar negligible.

We are the well-known supplier of Adiabatic Type HCL Gas Absorber that fulfills the need of various industrial places. This absorber is used for absorption of hydrochloric gas, which statutorily is not permitted to vent into the atmosphere. It also prevents the production of HCL acid. The HCL Gas Absorber is constructed with a series of packed sections and high quality components. The offered Adiabatic Type HCL Gas Absorber is highly demanded for its durability, safe use, easy maintenance and economical price.

Features:

  • High efficiency
  • Reliable performance
  • Long service life

HCL Gas Absorber (Adiabatic Type)

Process Description

HCL absorption columns are used for absorption of Hydrochloric gas, which statutorily are not permitted to vent into the atmosphere, and to produce the HCl acid.

The column is constructed with a series of packed sections, a gas introduction point below that, a condenser on the top, and a cooler at the bottom. Make water is sprayed from the top and acid is collected from the bottom.

HCL absorption columns are available in 80DN to 300DN diameter (for the gas rate 10 Kgs/hrto 300 Kgs/hrapprox).

TECHNICAL SPECIFICATION

PACKED COLUMN CONDENSER HTA GAS RATE (APPROX.) CAT. REF.
80mm x 3m 0.35m 2×2 10Kg/hr HCL 3
100mm x 4m 0.5m 2×2 20Kg/hr HCL 4
150mm x 4m 1.5m 2×2 60Kg/hr HCL 6
225mm x 4.5m 2.5m 2×2 150Kg/hr HCL 9
300mm x 4.5m 2.5m 2×2 300Kg/hr HCL 12

Main Export Market(s)

Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa

View Our Company Video